World of work silver-organisational awareness - Essay Example From the feedback, I have learnt that it is easier to use culture and factors as the key guiding principles for the external analysis of the organization. Thus, using a SWOT analysis facilitates in determining the strengths, weaknesses, opportunities and the threats that an organization has towards the social based factors. Further, having a well-developed topic for research will assist to make it easy to achieve success in the research process. This occurs because the answering of the topic comprises of the details essential for the achievement of success. I will use the experience to create a chance for identification and evaluation of the organization that I need to work in the future. Such is because entering into an organization without knowing the functions and activities of such organization may prove challenging to me. Hence, having awareness on the organization activities will create an effective opportunity of understanding the nature of the organization and the need for ensuring that it is easy to achieve organization success. It also ensures that I am able to identify the right organization based on personal dream and

Tuesday, February 4, 2020

Data Center Design Research Paper Example | Topics and Well Written Essays - 2000 words

Data Center Design - Research Paper Example Before designing the air cooled system, the amount of heat produced must be quantified. This is either in calories, joules, Tons or BTU. To determine the heat output of the system, the total quantity of heat produced by the hardware and their components when fully functional must be quantified. This hardware components include the Uninterruptable Power Supplies (UPS), the Information Technology Equipment, lighting and people working in the data center building. As it had been stated earlier, some of the hardware equipment to be used in the data center are NetApp 2050, HP C7000 Blade enclosure, and KVM. Each of this equipment has different minimum ventilation requirements. To install HP C7000 Blade enclosure, there are several minimum requirements. For good efficiency of HP C7000 Blade enclosure, there are different rack requirements. According to HP C7000 Blade enclosure documentation (Hewlett-Packard Development Company, 2010), HP C7000 Blade enclosure is optimized to work with 1000 0 series racks. Thus to facilitate adequate airflow and to allow for servicing, the spatial requirements below are considered. †¢Ã‚  A clearance of approximately 0.635 meters is left at the front part of the rack†¢Ã‚  At the back, a clearance of 0.762 meters is left to facilitate †¢Ã‚  In case of multiple racks, approximately 1.219 meters is left between the back of one rack and the rear of the adjacent racks. The design of HP C7000 Blade enclosure is in such a way that cool air is drawn into the system from the front part to cool the system.... Room ventilation The data center is composed of servers, routers, switches, among other hardware. All this are electronic devices which produces heat. This heat if not well eliminated, can destroy the electronic components in the hardware contained in the data center. Air – cooled systems are mostly used in data centers since most of the equipment are air – cooled. In this project, considering the number of hardware used and the software run on the systems, an air cooled system will be efficient. Before designing the air cooled system, the amount of heat produced must be quantified. This is either in calories, joules, Tons or BTU. To determine the heat output of the system, the total quantity of heat produced by the hardware and their components when fully functional must be quantified. This hardware components include the Uninterruptable Power Supplies (UPS), the Information Technology Equipment, lighting and people working in the data center building. As it had been s tated earlier, some of the hardware equipment to be used in the data center are NetApp 2050, HP C7000 Blade enclosure, and KVM. Each of this equipment has different minimum ventilation requirements. To install HP C7000 Blade enclosure, there are several minimum requirements. For good efficiency of HP C7000 Blade enclosure, there are different rack requirements. According to HP C7000 Blade enclosure documentation (Hewlett-Packard Development Company, 2010), HP C7000 Blade enclosure is optimized to work with 10000 series racks. Thus to facilitate adequate airflow and to allow for servicing, the spatial requirements below are considered. A clearance of approximately 0.635 meters is left at the front part of the rack At the back, a clearance of 0.762 meters is left to facilitate